Advanced optical system - Unparalleled performance from a benchtop photometer
Features 12 different programmed methods measuring 11 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves

One meter Top of Formfor both photometric and pH measurements, this compact, multi-parameter photometer for use in pool and spa applications, is one of the most advanced photometers available with an innovative optical design which utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.

Key features:

  • Advanced optical system with brighter, long-lasting LED light source
  • Backlit 128 x 64 Pixel Graphic Liquid Crystal Display
  • Built-in Reaction Timer for Photometric Measurements
  • Absorbance mode - concentration versus absorbance
  • Units of Measurement plus chemical form displayed
  • Result conversion at the touch of a button
  • Cuvette cover
  • pH and temperature measurement with a single digital probe
  • Good Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability
  • CAL Check alerts user to potential problems during the calibration process
  • Data Logging - Up to 1000 photometric and pH readings can be stored.
  • Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.
  • Battery Status Indicator
  • Error Messages
Click here for full description
Description

Details

Advanced optical system - Unparalleled performance from a benchtop photometer
Features 12 different programmed methods measuring 11 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users who would like to develop their own concentration versus absorbance curves

One meter Top of Formfor both photometric and pH measurements, this compact, multi-parameter photometer for use in pool and spa applications, is one of the most advanced photometers available with an innovative optical design which utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.

Key features:

  • Advanced optical system with brighter, long-lasting LED light source
  • Backlit 128 x 64 Pixel Graphic Liquid Crystal Display
  • Built-in Reaction Timer for Photometric Measurements
  • Absorbance mode - concentration versus absorbance
  • Units of Measurement plus chemical form displayed
  • Result conversion at the touch of a button
  • Cuvette cover
  • pH and temperature measurement with a single digital probe
  • Good Laboratory Practice (GLP) - track calibration information including date, time, buffers used, offset and slope for traceability
  • CAL Check alerts user to potential problems during the calibration process
  • Data Logging - Up to 1000 photometric and pH readings can be stored.
  • Logged readings can be quickly and easily transferred to a flash drive or to a PC. Data is exported as a .CSV file for use with spreadsheet programs.
  • Battery Status Indicator
  • Error Messages

High Efficiency LED Light Source

An LED light source offers superior performance compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components and electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.

High Quality Narrow Band Interference Filters

The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.

Reference Detector for a Stable Light Source

A beam splitter is used as part of the internal reference system of the HI-83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.

Large Cuvette Size

The sample cell of the HI-83326 fits a round glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Focusing Lens for Greater Light Yield

Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.

Specification

Input Channels 1 pH electrode input and 3 photometer wavelengths
pH Electrode Digital pH electrode (not included)
Logging type Log on demand with user name and sample ID optional input
Logging Memory 1000 readings
Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity
GLP Calibration data for connected pH electrode
Display 128 x 64 pixel LCD with backlight
Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement
Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing
Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8")
Weight 1.0 kg (2.2lbs)
Photometer/Colorimeter Light Source 3 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters
Photometer/Colorimeter Light Detector Silicon Photodetector
Bandpass filter Bandwidth 8nm
Bandpass filter wavelength accruacy ±1nm
Cuvette Type Round, 24.6mm
Number of Methods 128 Max
Ordering Information HI-83326 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

Tests

ALKALINITY
Alkalinity Range 0 to 500 mg/L (as CaCO3)
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Bromocresol green Method
BROMINE
Bromine Range 0.00 to 8.00 mg/L (as Br2)
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.
CHLORINE
Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method
COPPER
Copper Range High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution 0.01 mg/L
Copper Accuracy High Range ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA bicinchoninate method
CYANURIC ACID
Cyanuric Acid Range 0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method
HARDNESS, CALCIUM
Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
IRON
Iron Range High Range: 0.00 to 5.00 mg/L (as Fe)
Iron Resolution 0.01 mg/L
Iron Accuracy High Range: ±0.04 mg/L ±2% of reading
Iron Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters
NITRATE
Nitrate Range 0.0 to 30.0 mg/L (as NO3-- N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method
OZONE
Ozone Range 0.00 to 2.00 mg/L (as O3)
Ozone Resolution 0.01 mg/L
Ozone Accuracy ±0.02 mg/L ±3% of reading
Ozone Method Colorimetric DPD Method
pH
pH Range Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH
pH Resolution Photometer: 0.1 pH pH electrode: 0.1 pH
pH Accuracy Photometer: ±0.1 pH pH electrode: ±0.01 pH
pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
pH Method Photometer: phenol red
pH-mV Range ±1000 mV
pH-mV Resolution 0.1 mV
pH-mV Accuracy ±0.2 mV
PHOSPHATE
Phosphate Range Low Range: 0.00 to 2.50 mg/L (as PO43-)
Phosphate Resolution 0.01 mg/L
Phosphate Accuracy Low Range: ±0.04 mg/L ±4% of reading
Phosphate Method Low Range: Adaptation of the Ascorbic Acid method

REAGENTS

Alkalinity HI-93755-01 (100 tests); HI-93755-03 (300 tests)
Bromine HI-93716-01 (100 tests); HI-93716-03 (300 tests)
Chlorine - Free Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)
Chlorine Total HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93701-T (300 tests liquid)
Chlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)
Copper – HR HR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)
Cyanuric Acid HI-93722-01 (100 tests); HI-93722-03 (300 tests)
Hardness, Calcium HI-93720-01 (100 tests); HI-93720-03 (300 tests)
Iron – HR HR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)
Nitrate HI-93728-01 (100 tests); HI-93728-03 (300 tests)
Ozone HI-93757-01 (100 tests); HI-93757-03 (300 tests)
pH HI-93710-01 (100 tests); HI-93710-03 (300 tests)
Phosphate - LR LR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)


Ask a question

Carriage
Carriage

NOTE: Carriage charges calculated after order submission.

  • For credit account holders we will add any carriage charges due to your invoice, please contact us if you need the carriage charge before raising a purchase order number.
  • For non-credit account holders you will be advised of any carriage charges at time of payment.
    DO NOT send payment before carriage charge is confirmed.

Carriage will be charged at cost as follows:

  • UK Mainland - orders below £500.00 nett
  • Rest of UK - orders below £1,000.00 nett
  • Eire and the Channel Islands - all orders
  • All product codes marked
  • All bespoke/non-catalogue products
Payment
Minimum Order £50.00

A minimum order value of £50.00 nett will apply to non-credit account holders.
Orders below this value will not be processed.

Payment

Please note payment cannot be actioned on the JPL website…
JPL Credit Account holders: Create order and submit for immediate attention. Please remember delivery address and purchase order number will be required for us to process the order on account.
Note: We will add any carriage charges due to your invoice, please contact us if you need the carriage charge before raising a purchase order number.

Non-Credit Account holders: Create order and submit for immediate attention, please ensure you include a contact name, email address and telephone number so we can contact you with any carriage charges and take payment details over the phone. Alternatively after submitting your order call JPL on +44 (0)1788 542777 to check carriage charges and supply payment details.

All prices in British Pound Sterling (GBP)

VAT

All prices are subject to VAT at the prevailing rate except where marked †.
Orders to the EU are subject to UK VAT unless customer's VAT No. is given.
All prices in Pounds Sterling.

Claims & Returns
Claims & Returns

Please advise us immediately upon receipt of goods of shortages, non-delivery or damage in transit.

If returning goods for credit please state invoice number under which they were received.
Unless a genuine complaint against the quality of goods or an error on our part is justified a handling charge of up to 25% will apply.
Customers are responsible for carriage costs when returning goods.